The procedure for updating, restarting, or obtaining logs varies depending on the installation method (Docker CLI, Docker Compose, Portainer, etc.). Please choose the option that best suits your needs and with which you have configured your voraus.runtime.

4.1. Software Update

The recommended way to update the voraus.core is via Portainer. However, it is also possible to update via plain Docker CLI commands.

Warning

Before performing a software update, please carefully check the release notes for any compatibility notices. Note that if you skip versions, you have to consider all release notes between your currently installed version and the version you are about to install.

4.1.1. Update via Portainer

Download the voraus.core Docker image and upload it to Portainer (Fig. 61):

  1. Open the Portainer UI.

  2. Open the Images page.

  3. Click on the Import button.

  4. Click on the Select file button and select the Docker image file. You do not need to specify an image name.

  5. Press the Upload button and wait for the confirmation.

Import Docker images to Portainer

Fig. 61 Import Docker images to Portainer

Existing stacks will automatically use the new Docker image on the next restart.

If you pinned the image version of your software stack to a specific tag other than main-latest, update it in your stack configuration.

4.1.2. Update via Docker CLI

Stop the voraus.core via

docker compose -f path/to/your/composefile down

Download the voraus.core Docker image archive and load it via

docker load -i docker-images-X.X.X.tar.gz

If you pinned the image version of your voraus.core to a specific tag other than main-latest in the compose file, update it to the new version.

Start the voraus.core again via

docker compose -f path/to/your/composefile up -d

4.2. Troubleshooting

4.2.1. Restart the voraus.core

If, at any point, a software restart is necessary, the voraus.core can be restarted by stopping and starting the Portainer stack:

  1. Open the stack of the voraus.core.

  2. Stop the stack, wait until it stopped and restart it afterwards (Fig. 62).

Warning

Note that all unsaved data will be lost!

Stopping a stack

Fig. 62 Restarting a stack

Alternatively a restart can also be performed via Docker compose CLI commands. Stop the voraus.core with:

docker compose -f path/to/your/composefile down

And start again with:

docker compose -f path/to/your/composefile up -d

4.2.2. Python Syntax error

When writing your own commands in Python or using the Run Script command, syntax errors in the Python code might occur. These are usually signaled by the error codes CA37 or CB37.

HMI error message of a Python syntax error

Fig. 63 HMI error message of a Python syntax error

To see the cause of the error, the System Control log is helpful, which can be accessed as described in the Logging chapter. In many cases the log shows the exact location of the syntax error. If the Python interpreter can not locate the error (e.g. missing brackets), the line number in the executed Python file is displayed. In this case, refer to the Accessing the File System chapter to view the program code and find the error manually.

4.3. License Activation

The voraus.core software requires an activated license to run properly. After the successful installation of the voraus.core, the software will start in error state, because no license key is activated yet. To activate the license, simply complete the following steps.

The licenses can be activated in three different ways, choose:

Note

If you are using the voraus.ipc, the Linux operating system and the voraus.core are pre-installed, including a license key.

4.3.1. Online License Activation

Requirements

  • A valid license key with the format XXXXX-XXXXX-XXXXX-XXXXX-XXXXX

  • A system with internet connection

  • A laptop or PC

Instructions

  1. In the Settings menu, click the LICENSES button in the left tab to open the license page and click on click on ONLINE ACTIVATION (Fig. 64).

  2. Enter the ticket ID (license key) in the text field and press NEXT.

license activation

Fig. 64 Enter Licenses

  1. Select the license you wish to activate on the system (Fig. 65) and press NEXT.

license selection

Fig. 65 Licenses selection

  1. Wait until the activation has finished (Fig. 66) and press DONE.

license activation

Fig. 66 Licenses activation

  1. Restart the system by restarting the container or the system. The license is now activated and the system states are valid.

4.3.2. Offline License Activation

Requirements

  • A valid license key with the format XXXXX-XXXXX-XXXXX-XXXXX-XXXXX

  • A system without internet connection

  • A laptop or PC with internet connection

Instructions

  1. In the Settings menu, click the LICENSES button in the left tab to open the license page and click on click on OFFLINE ACTIVATION (Fig. 67).

license activation

Fig. 67 Select offline activation

  1. Select the license container from the drop-down on the left if a license container already exists on the system and click NEXT (Fig. 68).

    If you want to create a new license container, download the vorausrobotik.WibuCmLif file, click on SELECT FILE and select the downloaded file and click NEXT (Fig. 68).

license activation

Fig. 68 Select or create license container

  1. Enter the firmcode (6001996 for vorausrobotik) and click on NEXT (Fig. 69).

license activation

Fig. 69 Enter the firmcode

  1. Click DOWNLOAD CONTEXT FILE and click NEXT when the file has been downloaded (Fig. 70).

license activation

Fig. 70 Download the context file

  1. Open the Web Depot in a new tab and enter the ticket ID (license key), click Next (Fig. 71).

license activation

Fig. 71 Enter ticket ID (license key)

  1. The licenses in the ticket are shown, click Activate Licenses (Fig. 72).

license activation

Fig. 72 Licenses in the ticket

  1. Click CmActLicense (Fig. 73).

license activation

Fig. 73 Select license container type

  1. Click File-based license transfer (Fig. 74).

license activation

Fig. 74 Select license container type

  1. Select the licenses for activation, click Choose File and select the context file (WibuCmRac) which has been downloaded previously, click Start Activation Now (Fig. 75).

license activation

Fig. 75 Select licenses and start activation

  1. Click Download License Update File Now (Fig. 76).

license activation

Fig. 76 Download license update file

  1. In the voraus.operator click SELECT FILE and select the license update file (WibuCmRaU) and click NEXT when the update has been loaded successfully (Fig. 77).

license activation

Fig. 77 Upload the license update file

  1. Click DOWNLOAD RECEIPT FILE (Fig. 78).

license activation

Fig. 78 Download the receipt file

  1. In the Web Depot click Next (Fig. 79).

license activation

Fig. 79 Next step in Web Depot

  1. Click Choose File and select the receipt file (WibuCmRaC), click Upload Receipt Now (Fig. 80).

license activation

Fig. 80 Upload the receipt file

  1. The license transfer has been completed successfully, click OK (Fig. 81).

license activation

Fig. 81 License activation success

  1. In the voraus.operator click DONE (Fig. 82).

license activation

Fig. 82 Finish the license activation

  1. Click on LICENSES to verify the license activation (Fig. 83).

license activation

Fig. 83 Newly actived licenses

  1. Restart the system by restarting the container or the system. The license is now activated and the system states are valid.

4.3.3. Dongle License Activation

Requirements

  • A valid license key with the format XXXXX-XXXXX-XXXXX-XXXXX-XXXXX

  • A CodeMeter USB license dongle

  • A laptop or PC with internet connection

Note

If the USB license dongle has already been delivered with activated licenses, it only needs to be connected to the system. Restart the system after plugging in the USB dongle.

If you have received an empty USB license dongle or would like to activate additional licenses on an already used dongle, follow the steps below.

Instructions

  1. Stop the system and bring it into a safe state.

  2. Remove the USB license dongle from the system and connect it to a laptop or PC with an internet connection.

  3. Open the Web Depot and enter the ticket ID (license key), click Next (Fig. 84).

license activation

Fig. 84 Enter ticket ID (license key)

  1. The licenses in the ticket are shown, click Activate Licenses (Fig. 85).

license activation

Fig. 85 Licenses in the ticket

  1. Click CmDongle (Fig. 86).

license activation

Fig. 86 Select license container type

  1. Select the USB Dongle serial number and click Activate Selected Licenses Now (Fig. 87).

license activation

Fig. 87 Select license container type

  1. Wait until the license transfer has been completed (Fig. 88).

license activation

Fig. 88 Select license container type

  1. License transfer has been completed successfully, click OK (Fig. 89).

license activation

Fig. 89 Select license container type

  1. Reconnect the USB license dongle to the system.

  2. Restart the vorausrobotik software or the system.

Note

If dongle activation is required but no CodeMeter dongle is part of the setup, please contact the support.

4.4. License Overview

To view the active licenses complete the following steps:

  1. Navigate to the Settings menu and click the LICENSES button in the left tab to open the license page.

  2. Click on LICENSES to the an overview of the active licenses (Fig. 90).

license activation

Fig. 90 license overview

4.5. Logging

4.5.1. Download Log Files via voraus.operator

  1. To obtain the current log files, open the Service tab in the settings (Fig. 91/) and click on the Request Logfile button (Fig. 91/).

  2. The log file (ZIP format) will be downloaded.

Download log file

Fig. 91 Download log file

4.5.2. Live Log View

If you have access to the advanced settings you can see the live logs of some components directly inside the voraus.operator. Use the URL parameter ?advanced to enable the ADVANCED tab in the settings page and enter the password to get to the advanced settings page. The logs can be found in the LOG tab and the component can be selected via the dropdown menu (Fig. 92). If you do not have the password for this option, please contact us on our website www.vorausrobotik.com.

Note

Not all components might be available for all robot types.

Live logs of System Control to see the cause of a Python syntax error

Fig. 92 Live logs of System Control to see the cause of a Python syntax error

4.5.3. View Logs from Portainer

To see the logs of the current Portainer stack, open the stack page and click on the logs icon next to the voraus.core container (Fig. 93).

View container logs

Fig. 93 View container logs

On the logs page you can view the latest logs of all voraus components and download them as a txt-file by clicking the Download logs button. In order to see the full logs, it is recommended to increase the line count in the Lines input field.

Logs of the current container

Fig. 94 Logs of the current container

4.5.4. Accessing the File System

To view the content of single files on the system (e.g. programs) you have to connect to the console by clicking the console icon next to the voraus.core container (Fig. 95).

Open the container console

Fig. 95 Open the container console

Afterwards you need to connect to the console by clicking the Connect button (Fig. 96) and you are logged in as the root user. Change the directory to /root/data/voraus/userapp to view all programs and use the cat command to show their content.

Click the connect button to open the console

Fig. 96 Click the connect button to open the console

Docker volumes are stored on the file system of the Docker host machine, so they can be directly accessed by the host (assuming you have root rights on the Docker host). On Linux, the content of Docker volumes is stored under /var/lib/docker/volumes/. You should not modify anything here, as it can lead to unexpected behavior. However, it can be useful for monitoring log messages, for example, this command will print all logs of the component voraus-robot-control-py:

sudo tail -f /var/lib/docker/volumes/docker_voraus_log_volume/_data/voraus-robot-control.log